The global shipping industry faces pressure to meet the International Maritime Organization (IMO)'s 2050 net-zero emission target. Amid the combined impact of the EU Emissions Trading System (EU ETS) and FuelEU Maritime, shipowners urgently need quantifiable and verifiable emission reduction solutions.
Typ :
EmissionGuard CGC-600SIGAS EmissionGuard CGC-600 delivers real-time online monitoring of exhaust gases and characteristic pollutants emitted by ships.
Applying Method D, the EU-recognized official emission calculation method, it enables compliant emission management based on precise data. Meanwhile, it contributes to more accurate carbon tax calculation, creating a sustainable and cost-effective operational environment for maritime vessels.
Measurement Gases:
• Nitric Oxide NO
• Nitrogen Dioxide NO2
• Sulfur Dioxide SO2
• Methane CH4
• Carbon Dioxide CO2
• Carbon Monoxide CO
• Oxygen O2
• Methanol CH4O
Product Features:
- Full-spectrum real-time monitoring and analysis of gases: NO, NO₂, SO₂, CH₄, CO₂, CO, O₂, CH₄O, with detection accuracy ≤±1% FS
- Monitor and calculate greenhouse gas (GHG) emissions in accordance with EU MRV and IMO regulations and generate compliant reports
- Expandable to N₂O and NH₃ for future regulatory requirements
- Multi-stack management, up to 8 measuring points
- Real-time evaluation of engine combustion efficiency via exhaust gas analysis
- Compact cabinet design, cabin door accessible
- IP54 wall-mounted cabinet with shock & salt spray corrosion resistance
- Modular design enables easy upgrade / expansion and low maintenance
- Certified by classification societies including ABS, DNV, BV, LR, CCS
Specification:
|
Parameter |
Specifications |
|
Measuring Points |
1-8 (Customized) |
|
Measured Gases |
NO, NO2, SO2, CH4, CO2, CO, O2, CH4O, NH3, N2O, etc |
|
Measurement Principles |
NDIR, NDUV, TCD, EC, TDLAS, DOAS, PID |
|
Measuring Ranges |
ppm、Vol.-%;(Customized) |
|
Accuracy |
≤±1% FS |
|
Response Time |
T90 < 30s |
|
Linear Error |
≤±1% FS |
|
Span Drift |
≤±0.5% FS |
|
Zero Drift |
≤±0.5% FS |
|
Output Signal |
4-20mA / Relay (Alarm) |
|
Digital Signal |
RS232, RS485, TCP/IP |
|
Power Supply |
220VA 50/60 Hz 3φ |
|
Rated Power |
3.0KW (Cabinet); 60W/m (Heat-tracing tube) |
|
Enclosure Rating |
IP54 |
|
Ambient Temperature |
5℃ ~ 60℃ (Cabinet); -20℃ ~ 80℃ (Probe and heat-tracing tube); Customized |
|
Ambient Humidity |
< 90% RH (non-condensing) |
|
Storage Temperature |
-20℃ ~ 60℃ |
|
Instrument Air |
Quality level: not lower than ISO 8573-2010 3-4-3; Gas usage:0.5m3/h (Per Sampling Probe); Pressure: 0.4-0.8MPa |
|
Cabinet Dimensions |
Analyzer Cabinet (800×450×1000mm); Sample Cabinet (700×350×600mm); Optional temperature control, Customized |
|
System Composition |
Sampling unit: Sampling probe S-Probe M100; Transmission unit: Electric heating and tracing pipeline; Processing unit: High-Efficiency Multi-Stage Filtration; Pressure & Flow Stabilization; Condensation unit: Smart Condensation System GC 3113 Analysis unit: S-ANALYZER series multi-component gas analyzer Gas parameters: Ultrasonic Flowmeter, Humidity sensor (optional) Control unit: Self-running, Self-diagnosing Data unit: Data report, Data interaction |